← All services← 全部服务 / Networks & Wi-Fi网络 & Wi-Fi
34 live sites在线站点 · SVC-06 / 09
Site survey · measured, not guessed 现场勘测 · 量出来,不靠猜

Wi-Fi that reaches the back room. Networks that segment for real. 覆盖到后厨 的 Wi-Fi。真分段 的网络。

Heat-map first, AP placement measured, VLANs that actually segment guest from staff from IoT. UniFi · Meraki · pfSense · Tailscale — documented down to the patch panel. 先出热力图,AP 位置量出来,VLAN 真的把访客 / 员工 / IoT 分开。UniFi · Meraki · pfSense · Tailscale —— 文档详细到配线架。

Live sites在线站点
34monitored
APs deployed已部署 AP
1.4k+
Median uptime中位可用
99.99%
Surveys / yr年勘测数
60+
The work · 06 patterns能做什么 · 六种类型

Six things we install, often.六种我们 常装 的网络。

Every project starts with a site survey. The survey decides the next two patterns; we don't have a template you'll get bolted into.每个项目都从现场勘测开始。勘测决定接下来做哪两件事;我们没有把你硬塞进去的"模板套餐"。

PATTERN · 01

Site survey现场 勘测

Walk the building with real measurement gear, map the dead zones, identify the cable runs you already have, and write up a 12-page report you can act on.用真测量设备走遍建筑、标出死角、识别已有布线、出一份 12 页可执行的报告。

Heat-mapCable auditRF interferenceConcrete & steel
PATTERN · 02

Greenfield install全新 部署

New office, new build-out, or replacing a pile of consumer gear. APs, switches, firewall, cabling — measured, racked, labelled.新办公室、新装修、或者把一堆消费级设备替换掉。AP、交换机、防火墙、布线 —— 测过、上架、贴标。

AP placementSwitch & rackFirewallCabling
PATTERN · 03

Mesh extensionMesh 扩展

Older building, no spare conduit, no fishing cables through 1970s plaster — mesh APs strategically placed to cover the awkward corners.老楼、没线槽、不可能在 1970 年代石膏板里穿线 —— 用 mesh AP 战略性地把死角补上。

Mesh APPoE injectorRoaming tuneBackhaul
PATTERN · 04

VPN setupVPN 部署

Tailscale or WireGuard for staff, IPsec site-to-site between offices, accountant-friendly clients on macOS / Windows / iOS / Android.员工用 Tailscale 或 WireGuard,办公室之间走 IPsec,会计用 macOS / Windows / iOS / Android 都顺手。

TailscaleWireGuardIPsec site-to-siteAlways-on
PATTERN · 05

Segmentation网络 分段

VLANs that actually segment: guest, staff, IoT, security cameras, payment terminals — each in its own broadcast domain with explicit ACLs.真分段的 VLAN:访客 / 员工 / IoT / 监控 / 收银 —— 各自独立广播域,ACL 明确写出来。

Guest VLANIoT VLANPOS VLANACL matrix
PATTERN · 06

Bandwidth & monitoring带宽 & 监控

PRTG / LibreNMS / UISP dashboards, alert thresholds tuned for your traffic, monthly bandwidth report. ISP under-delivers? You'll have proof.PRTG / LibreNMS / UISP 看板、告警阈值按你的流量调、月度带宽报告。ISP 没达标?你有证据。

PRTGLibreNMSUISPBandwidth log
How an install unfolds · 05 phases部署怎么走 · 五个阶段

Five phases,
each measured, never guessed.
五个阶段,每一步都
测过,不靠猜。

Survey before quote, quote before order, order before drilling. Most other shops do it backwards — and that's why their installs ship with 1.4× the AP count "just in case."先勘测后报价、先报价后下单、先下单后钻孔。多数公司反着做 —— 所以他们的方案里多 40% 的 AP "以防万一"。

PHASE 01
Survey勘测
2–4 days

Walk the building, measure every corner.走遍每个角落,逐点测量

A senior engineer on-site with Ekahau / NetSpot, crawls every closet, traces every cable, photographs the patch panel. Output: a heat-map of current signal, a cable audit, an interference report, and a 12-page survey deck.资深工程师带着 Ekahau / NetSpot 上门,钻每个弱电井、追每根线、拍配线架。产出:当前信号热力图、布线审计、干扰报告、一份 12 页勘测报告。

Heat-mapCable auditSurvey deck
PHASE 02
Design设计
~1 wk

Topology, AP placement, VLAN map.拓扑、AP 位置、VLAN 图

A network diagram with every device, every VLAN, every ACL. AP placement marked on the floorplan with predicted coverage. Reviewed with you in a 60-min call before any equipment order.网络拓扑图列出每台设备、每个 VLAN、每条 ACL。平面图上标出 AP 位置 + 预测覆盖。下单前先开 60 分钟会过一遍。

Network diagramAP placementVLAN matrix
PHASE 03
Procure采购
1–3 wk

Order at zero markup, you see the receipt.采购 零加价,你看原始发票。

UniFi / Meraki / pfSense ordered through our distributor accounts, billed to you at our cost, receipt forwarded. We charge for the install hours, not the metal.UniFi / Meraki / pfSense 从我们的分销账号下单、按我们的成本转账给你、原始发票转交。我们只收装配工时。

PO listPass-through receiptLead-time tracking
PHASE 04
Install施工
2–5 days

Rack, cable, mount, label.上架、布线、安装、贴标

Two-person crew on-site (or three for larger jobs). Cabling Cat6/6a tested with Fluke certifier, every port labelled, patch panel photographed, every device added to the asset register.两人小组上门(大项目三人)。Cat6/6a 用 Fluke 认证仪测试、每个端口贴标、配线架拍照存档、每台设备进资产清册。

Fluke test reportLabelled patchAsset register
PHASE 05
Tune调优
1 wk + monitor

Verify, monitor, handover.验证、监控、交接

Post-install heat-map (compared to predicted). PRTG / UISP monitoring live with alert thresholds tuned. 30-day warranty on every install. Documentation in your shared drive, not ours.完工后再做一次热力图(对比预测)。PRTG / UISP 监控上线、告警阈值调好。每次安装含 30 天保修。文档进你共享盘,不是我们的。

Post-install heat-mapLive monitoring30-day warranty
The stack · what we install设备栈 · 我们装的东西

Boring tools, on purpose."无聊"的设备,是有意 选的。

If you've already standardized, we work in your stack. If we're picking — these are what we reach for, because they have a five-year roadmap and a real support phone line.已经标准化,我们用你的。让我们选 —— 这些是顺手的,因为有五年路线图、有真客服电话能打通。

CAT · 01Wi-FiWi-Fi
UniFiMerakiCiscoArubaMist
CAT · 02Routing & firewall路由 & 防火墙
UniFipfSenseFortiGateSonicWallOPNsense
CAT · 03VPNVPN
TailscaleWireGuardOpenVPNIPsecZeroTier
CAT · 04Segmentation分段
VLANsACLs802.1XRADIUSSDN (UniFi)
CAT · 05Monitoring监控
PRTGLibreNMSUISPUptime KumaZabbix
CAT · 06Cabling布线
Cat6Cat6aFiber (OM4)Fluke certifiedCat5e (legacy)
Asked, often · 06 questions常被问到 · 六个问题

The network questions, answered.关于 网络 的问题,直接回答。

If yours isn't here, write to [email protected]. A real engineer answers within 4 business hours.没列到的问题,发给 [email protected]。真人工程师 4 小时内回。

What's your service area?服务范围?

In-person: Metro Vancouver + Sunshine Coast + Whistler. Remote design + remote-hands install: anywhere in BC, Alberta, Washington, Oregon. Above 100 km from Vancouver we ship the cabler and bill travel.上门:大温 + 阳光海岸 + 惠斯勒。远程设计 + 远程协助安装:BC、阿尔伯塔、华盛顿、俄勒冈。距 Vancouver 超过 100 公里,布线工出差,差旅另计。

My building is old / has thick walls — can you cover it?我楼老 / 墙厚,能覆盖吗?

Almost always, yes — but the survey decides how. We've installed in 1920s heritage, 1960s concrete, and 1990s warehouses. Site survey is non-negotiable for these; that's why we don't quote without one.基本都能 —— 怎么做要看勘测。我们装过 1920 年代历史建筑、1960 年代混凝土楼、1990 年代仓库。这种楼不勘测就报价是耍流氓 —— 所以我们坚持先勘测。

Can we keep our existing ISP?现有 ISP 能保留吗?

Yes. We work with whatever you have — Telus, Shaw, Rogers, Novus, business fiber. We can also tell you when an ISP swap would actually pay back, and when it's just an annoying month for no upside.能。Telus、Shaw、Rogers、Novus、商用光纤,我们都对接过。我们也会直说:换 ISP 真能值回票价的时候、和"折腾一个月没好处"的时候。

Mesh vs cabled APs — which?Mesh 还是有线 AP?

Cabled when possible — better throughput, fewer surprises. Mesh when running a cable would mean tearing open a heritage wall. We'll tell you which on the survey, with measurements to back it up.能拉线就拉线 —— 吞吐稳、意外少。需要拆历史墙才能走线时再用 mesh。勘测时我们会告诉你哪种、并给出数据。

Guest Wi-Fi — included?访客 Wi-Fi 含吗?

Yes. Every install includes a guest VLAN with bandwidth caps, captive portal (your branding), and full isolation from staff / IoT / payment terminals. It's a five-minute config, but a one-day fix if it's missing.含。每次安装都建访客 VLAN,带宽限速、自带 captive 门户(你的品牌)、与员工 / IoT / 收银完全隔离。配五分钟、不补的话被攻破要修一整天。

Hardware lead time?硬件交期?

UniFi / Meraki: 1–3 weeks typically (sometimes longer when a model is allocated). Cabling: same week. We tell you the dates after the design phase, with two alternates if the lead time is ugly.UniFi / Meraki:通常 1–3 周(某些型号被分配时更久)。布线:本周就能到。设计阶段后我们告诉你具体日期,如果交期太丑,会给两个替代方案。

Wi-Fi flaky in the back room?后厨 Wi-Fi 总掉?

Book a site survey. A senior engineer walks the building, measures every corner, and writes up a 12-page deck with a fixed quote. No guesses, no upsell.预约一次现场勘测。资深工程师上门走遍楼里每个角落、逐点测量,出 12 页报告 + 固定报价。不靠猜、不强推。