Site survey现场 勘测
Walk the building with real measurement gear, map the dead zones, identify the cable runs you already have, and write up a 12-page report you can act on.用真测量设备走遍建筑、标出死角、识别已有布线、出一份 12 页可执行的报告。
Heat-map first, AP placement measured, VLANs that actually segment guest from staff from IoT. UniFi · Meraki · pfSense · Tailscale — documented down to the patch panel. 先出热力图,AP 位置量出来,VLAN 真的把访客 / 员工 / IoT 分开。UniFi · Meraki · pfSense · Tailscale —— 文档详细到配线架。
Every project starts with a site survey. The survey decides the next two patterns; we don't have a template you'll get bolted into.每个项目都从现场勘测开始。勘测决定接下来做哪两件事;我们没有把你硬塞进去的"模板套餐"。
Walk the building with real measurement gear, map the dead zones, identify the cable runs you already have, and write up a 12-page report you can act on.用真测量设备走遍建筑、标出死角、识别已有布线、出一份 12 页可执行的报告。
New office, new build-out, or replacing a pile of consumer gear. APs, switches, firewall, cabling — measured, racked, labelled.新办公室、新装修、或者把一堆消费级设备替换掉。AP、交换机、防火墙、布线 —— 测过、上架、贴标。
Older building, no spare conduit, no fishing cables through 1970s plaster — mesh APs strategically placed to cover the awkward corners.老楼、没线槽、不可能在 1970 年代石膏板里穿线 —— 用 mesh AP 战略性地把死角补上。
Tailscale or WireGuard for staff, IPsec site-to-site between offices, accountant-friendly clients on macOS / Windows / iOS / Android.员工用 Tailscale 或 WireGuard,办公室之间走 IPsec,会计用 macOS / Windows / iOS / Android 都顺手。
VLANs that actually segment: guest, staff, IoT, security cameras, payment terminals — each in its own broadcast domain with explicit ACLs.真分段的 VLAN:访客 / 员工 / IoT / 监控 / 收银 —— 各自独立广播域,ACL 明确写出来。
PRTG / LibreNMS / UISP dashboards, alert thresholds tuned for your traffic, monthly bandwidth report. ISP under-delivers? You'll have proof.PRTG / LibreNMS / UISP 看板、告警阈值按你的流量调、月度带宽报告。ISP 没达标?你有证据。
Survey before quote, quote before order, order before drilling. Most other shops do it backwards — and that's why their installs ship with 1.4× the AP count "just in case."先勘测后报价、先报价后下单、先下单后钻孔。多数公司反着做 —— 所以他们的方案里多 40% 的 AP "以防万一"。
A senior engineer on-site with Ekahau / NetSpot, crawls every closet, traces every cable, photographs the patch panel. Output: a heat-map of current signal, a cable audit, an interference report, and a 12-page survey deck.资深工程师带着 Ekahau / NetSpot 上门,钻每个弱电井、追每根线、拍配线架。产出:当前信号热力图、布线审计、干扰报告、一份 12 页勘测报告。
A network diagram with every device, every VLAN, every ACL. AP placement marked on the floorplan with predicted coverage. Reviewed with you in a 60-min call before any equipment order.网络拓扑图列出每台设备、每个 VLAN、每条 ACL。平面图上标出 AP 位置 + 预测覆盖。下单前先开 60 分钟会过一遍。
UniFi / Meraki / pfSense ordered through our distributor accounts, billed to you at our cost, receipt forwarded. We charge for the install hours, not the metal.UniFi / Meraki / pfSense 从我们的分销账号下单、按我们的成本转账给你、原始发票转交。我们只收装配工时。
Two-person crew on-site (or three for larger jobs). Cabling Cat6/6a tested with Fluke certifier, every port labelled, patch panel photographed, every device added to the asset register.两人小组上门(大项目三人)。Cat6/6a 用 Fluke 认证仪测试、每个端口贴标、配线架拍照存档、每台设备进资产清册。
Post-install heat-map (compared to predicted). PRTG / UISP monitoring live with alert thresholds tuned. 30-day warranty on every install. Documentation in your shared drive, not ours.完工后再做一次热力图(对比预测)。PRTG / UISP 监控上线、告警阈值调好。每次安装含 30 天保修。文档进你共享盘,不是我们的。
If you've already standardized, we work in your stack. If we're picking — these are what we reach for, because they have a five-year roadmap and a real support phone line.已经标准化,我们用你的。让我们选 —— 这些是顺手的,因为有五年路线图、有真客服电话能打通。
If yours isn't here, write to [email protected]. A real engineer answers within 4 business hours.没列到的问题,发给 [email protected]。真人工程师 4 小时内回。
In-person: Metro Vancouver + Sunshine Coast + Whistler. Remote design + remote-hands install: anywhere in BC, Alberta, Washington, Oregon. Above 100 km from Vancouver we ship the cabler and bill travel.上门:大温 + 阳光海岸 + 惠斯勒。远程设计 + 远程协助安装:BC、阿尔伯塔、华盛顿、俄勒冈。距 Vancouver 超过 100 公里,布线工出差,差旅另计。
Almost always, yes — but the survey decides how. We've installed in 1920s heritage, 1960s concrete, and 1990s warehouses. Site survey is non-negotiable for these; that's why we don't quote without one.基本都能 —— 怎么做要看勘测。我们装过 1920 年代历史建筑、1960 年代混凝土楼、1990 年代仓库。这种楼不勘测就报价是耍流氓 —— 所以我们坚持先勘测。
Yes. We work with whatever you have — Telus, Shaw, Rogers, Novus, business fiber. We can also tell you when an ISP swap would actually pay back, and when it's just an annoying month for no upside.能。Telus、Shaw、Rogers、Novus、商用光纤,我们都对接过。我们也会直说:换 ISP 真能值回票价的时候、和"折腾一个月没好处"的时候。
Cabled when possible — better throughput, fewer surprises. Mesh when running a cable would mean tearing open a heritage wall. We'll tell you which on the survey, with measurements to back it up.能拉线就拉线 —— 吞吐稳、意外少。需要拆历史墙才能走线时再用 mesh。勘测时我们会告诉你哪种、并给出数据。
Yes. Every install includes a guest VLAN with bandwidth caps, captive portal (your branding), and full isolation from staff / IoT / payment terminals. It's a five-minute config, but a one-day fix if it's missing.含。每次安装都建访客 VLAN,带宽限速、自带 captive 门户(你的品牌)、与员工 / IoT / 收银完全隔离。配五分钟、不补的话被攻破要修一整天。
UniFi / Meraki: 1–3 weeks typically (sometimes longer when a model is allocated). Cabling: same week. We tell you the dates after the design phase, with two alternates if the lead time is ugly.UniFi / Meraki:通常 1–3 周(某些型号被分配时更久)。布线:本周就能到。设计阶段后我们告诉你具体日期,如果交期太丑,会给两个替代方案。